La Braquiterapia de alta tasa de dosis (HDR por sus siglas en inglés) cumple un papel de gran importancia en los tratamientos radiantes. Tradicionalmente, hasta fines de la década pasada, los equipos más difundidos para realizar Braquiterapia de alta tasa de dosis se han basado en Ir-192, pero en los últimos años se han introducido al mercado equipos con fuentes de Co-60, los cuales ya están siendo utilizados en varias instituciones oncológicas con una clara tendencia a ir en aumento. Para implementar esta tecnología, la institución debe poseer un recinto de irradiación, comúnmente llamado búnker, donde alojar el equipo y realizar la práctica clínica, el cual debe cumplir con los requerimientos exigidos por la Autoridad Regulatoria del país. Por consiguiente, si el búnker existente en la institución ha sido diseñado para Braquiterapia HDR con Ir-192 será necesaria la adecuación del mismo, ya que por las características radiantes del Co-60 en general es necesaria una adición de espesor en las barreras de protección. En este trabajo se diseña y presenta una metodología ágil y sencilla para el cálculo de las modificaciones que deben realizarse a un búnker de Braquiterapia HDR con Ir-192 que se desee utilizar para Braquiterapia HDR con Co-60. Para sustentar este proyecto y validar la metodología propuesta se hicieron uso de las recomendaciones emitidas por la Organismo Internacional de Energía Atómica en la Serie de reportes de seguridad N° 47 titulado “Radiation Protection in the Design of Radiotherapy Facilities” publicado en el año 2006 y del Consejo Nacional de Protección y Medición de Radiación (NCRP por sus siglas en inglés) en su Reporte N° 151 titulado “Structural Shielding Design and Evaluation for Megavoltage X and Gamma-Ray Radiotherapy Facilities”, publicado en el año 2005.

Resumen en inglés

High dose rate (HDR) brachytherapy plays a major role in radiation therapy. Traditionally, until the end of the last decade, the most widely used devices for high dose rate brachytherapy have been based on Ir-192 however, in recent years equipment with Co-60 sources has been introduced to the market and are being used in several oncological institutions with a clear tendency to increase. To implement this technology, the institution must have an irradiation facility, commonly called bunker, to install the equipment and perform the clinical practice. These facilities must comply with the requirements of the Regulatory Authority of the country. Therefore, if the existing bunker in the institution has been designed for HDR Brachytherapy with Ir-192, it will need to be adapted to use Cobalt 60 HDR, since the radiant characteristics of the Co-60 in general requires additional thickness in the protection barriers. In this work, a simple and agile methodology is designed and presented to calculate the modifications that must be made to such a bunker for HDR Brachytherapy with Ir-192 that is to be adapted for HDR Brachytherapy with Co-60. To support this project and to validate the proposed methodology, it were used the recommendations issued by the International Atomic Energy Agency (IAEA) in Safety Report Series No. 47 entitled "Radiation Protection in the Design of Radiotherapy Facilities" published in 2006, as well as those published in 2005 by the National Council for Radiation Protection and Measurement (NCRP) in its Report No. 151 entitled "Structural Shielding Design and Evaluation for Megavoltage X and Gamma Ray Radiotherapy Facilities".

Tipo de objeto:Tesis (Maestría en Física Médica)
Palabras Clave:Medicine; Medicina; Nuclear Medicine; Medicina Nuclear; Radioterapy; Radioterapia; Radioprotección; Brachytherapy; Braquiterapia; Cobalt 60; Cobalto 60; Iridium 192; Iridio 192; [ High dose rate; Alta tasa de dosis]
Materias:Medicina > Oncología
Medicina > Radioterapia
Medicina > Dosimetría
Divisiones:Hospital Oncológico de Córdoba
Código ID:571
Depositado Por:Tamara Cárcamo
Depositado En:04 Abr 2017 12:15
Última Modificación:09 May 2017 11:32

Personal del repositorio solamente: página de control del documento